產(chǎn)品詳情

UL1015聚氯乙烯絕緣單芯線申請認證流程
UL1028聚氨乙烯絕緣單芯線申請UL認證費用
UL1032聚氨乙烯絕緣單芯線申請UL認證費用,UL1061聚氯乙烯絕緣單芯線認證UL認證,UL1095聚氣乙烯絕緣電子線申請UL認證費用
UL1185單芯屏蔽線申請認證流程
UL1533單芯屏蔽線UL認證
UL1569聚氣乙烯絕緣單芯線UL認證
UL1571聚氨乙烯絕緣UL認證,單芯電子線UL1617聚氨乙烯絕緣加強型電線UL認證
UL1618聚氯乙烯絕緣加強型電線UL1672交聯(lián)聚乙烯絕緣加強型電線
UL10012聚氯乙烯絕緣電線申請認證流程
Appliance Wiring Material - Component
The materials covered under this category are incomplete in certain constructional features or restricted in perbance capabilities and are intended for use as components of complete equipment bted for investigation rather than for direct separate installation in the field. THE FINAL ACCEPTANCE OF THE COMPONENT IS DEPENDENT UPON ITS USE IN EQUIPMENT SUBMITTED TO UL.
USE
This category covers appliance wiring material (AWM) that has been tested in accordance with the established procedures to define certain properties in order to facilitate the investigation of its use in end-product equipment.
The wire/cable includes single- and multi-conductor constructions of a wide range of conductor sizes, insulation thickness, and materials. "Hook-up wire" and "lead wire" is covered under this category but not described as such. Wire is generally intended for the specific application as indicated on the tag, reel or smallest unit container. The voltage rating does not apply to voltage between conductors in a parallel or flat construction.
A construction in any of the sections may include a jacket. Specialty wire and/or cable is intended for a specific application as defined for that construction.
CONDITIONS OF ACCEPTABILITY
A style page is used to describe the construction of each style number. The style page includes inbation such as temperature and voltage rating, conductor size and material, insulation material and thickness, jacket material and thickness (if provided), a debion of any shields or coverings, the required markings, and the use statement. This inbation is used to determine the suitability of the particular wire construction for use in the particular application. A facing page may be used to modify the requirements on a style page or provide inbation in addition to what is on the style page. The facing page is proprietary for each manufacturer.
FLAME RATINGS
All AWM has a minimum flame rating as defined on the style page. AWM may be additionally investigated to one of the following international flame tests:
IEC 60332-1-1, "Tests on Electric and Optical Fibre Cables Under Fire Conditions - Part 1-1: Test for Vertical Flame Propagation for a Single Insulated Wire or Cable Apparatus"
IEC 60332-2-2, "Tests on Electric and Optical Fibre Cables Under Fire Conditions - Part 2-2: Test for Vertical Flame Propagation for a Single Small Insulated Wire or Cable - Procedure for Diffusion Flame"
IEC TS 60695-11-21, "Fire Hazard Testing - Part 11-21: Test Flames - 500 W Vertical Flame Test bbbbbb for Tubular Polymeric Materials"
聯(lián)系人:陶靜Sunny13913142465 QQ:1822971259