產品詳情
SCONINC變換器SCONI-1200-C8Y,出售大秦 DSRC-5A-2CREVIS,ST-2924,4 Points, 24Vac/2A, 24Vdc/2A, 1 Points/1COM
CREVIS,ST-2944,4 Points, 24Vac/2A, 24Vdc/2A, 1Point/1Com
CREVIS,ST-2734,4 Points, 24~220Vac/0.5A, 24~220Vac/0.5A, 4Points, 1Ponit/1COM
CREVIS,ST-2852,Triac Output 2 Points, 12V ~ 125Vac / 0.5A
CREVIS,ST-2792,Relay Output 2 Points, TermiCREVIS,NAl,230Vac / 2A, CREVIS,MAnual Type
CREVIS,ST-2748,Relay Output 8 Points, TermiCREVIS,NAl, 230Vac / 2A, 24Vdc/2A
CREVIS,ST-2744,Relay Output 4 Points, TermiCREVIS,NAl, 230Vac / 2A, 24Vdc/2A
CREVIS,ST-2742,Relay Output 2 Points, TermiCREVIS,NAl,230Vac / 2A, 24Vdc/2A
CREVIS,ST-2624,Digital Output 4 Points, Source, TermiCREVIS,NAl, 24Vdc / 2A
CREVIS,ST-2524,Digital Output 4 Points, Source, TermiCREVIS,NAl, DiagnoCREVIS,STics, 24Vdc / 2A
CREVIS,ST-2614,Digital Output 4 Points, Sink, TermiCREVIS,NAl, 24Vdc / 2A
CREVIS,ST-2514,Digital Output 4 Points, Sink, TermiCREVIS,NAl, DiagnoCREVIS,STics, 24Vdc / 2A
CREVIS,ST-2424,Digital Output 4 Points, Source, TermiCREVIS,NAl, DiagnoCREVIS,STics, 24Vdc / 0.5A
CREVIS,ST-2328,Digital Output 8 Points, Source, TermiCREVIS,NAl, 24Vdc / 0.5A
CREVIS,ST-2324,Digital Output 4 Points, Source, TermiCREVIS,NAl, 24Vdc / 0.5A

因此,有時測得控制極反向電阻比較小,并不能說明控制極特性不好。另外,在測量控制極正反向電阻時,萬用表應R*10或R*1擋,防止電壓過高控制極反向擊穿。若測得元件陰陽極正反向已短路,或陽極與控制極短路,或控制極與陰極反向短路,或控制極與陰極斷路,說明元件已損壞??煽毓枋强煽毓枵髟暮喎Q,是一種具有三個PN結的四層結構的大功率半導體器件。實際上,可控硅的功用不僅是整流,它還可以用作無觸點開關以快速接通或切斷電路,實現將直流電變成交流電的逆變,將一種的交流電變成另一種的交流電,等等??煽毓韬推渌雽w器件一樣,其有體積小、效率高、性好、工作可靠等優點。它的出現,使半導體技術從弱電領域進入了強電領域。
CREVIS,ST-2414,Digital Output 4 Points, Sink, TermiCREVIS,NAl, DiagnoCREVIS,STics, 24Vdc / 0.5A
CREVIS,ST-2318,Digital Output 8 Points, Sink, TermiCREVIS,NAl, 24Vdc / 0.5A
CREVIS,ST-2314,Digital Output 4 Points, Sink, TermiCREVIS,NAl, 24Vdc / 0.5A
CREVIS,ST-222F,Digital Output 16 Points, Source, 20P Connector, 24Vdc / 0.5A
CREVIS,ST-221F,Digital Output 16 Points, Sink, 20P Connector, 24Vdc / 0.5A
CREVIS,ST-2124,Digital Output 4 Points, TTL Non- InveCREVIS,RTing, TermiCREVIS,NAl, 5Vdc / 20CREVIS,MA
CREVIS,ST-2114,Digital Output 4 Points, TTL InveCREVIS,RTing, TermiCREVIS,NAl, 5Vdc / 20CREVIS,MA
CREVIS,ST-1904,Digital Input 4 Points, 240Vac (AC 170V ~ 264V)
CREVIS,ST-1804,Digital Input 4 Points, 120Vac (AC 85V ~ 132V)
CREVIS,ST-132F,Digital Input 16 Points, Source, 20P Connector 48Vdc
CREVIS,ST-1324,Digital Input 4 Points, Source, TermiCREVIS,NAl, 48Vdc
CREVIS,ST-131F,Digital Input 16 Points, Sink, 20P Connector 48Vdc
CREVIS,ST-1314,Digital Input 4 Points, Sink, TermiCREVIS,NAl, 48Vdc
CREVIS,ST-122F,Digital Input 16 Points, Source, 20P Connector, 12V/24Vdc
CREVIS,ST-1228,Digital Input 8 Points, Source, TermiCREVIS,NAl, 12V / 24Vdc
CREVIS,ST-1224,Digital Input 4 Points, Source, TermiCREVIS,NAl, 12V / 24Vdc
CREVIS,ST-121F,Digital Input 16 Points, Sink, 20P Connector, 12V/24Vdc
而且可以大大意外事故損失,其主要功能有:●及時性。油田后方能夠實時每個區域、甚至每口油、氣井的生產動態,為快速制定生產和經營方案提供決策依據?!褡詣印T诔霈F意外情況,如輸油管線破裂,造成主管流量和分支管線流量之和產生較大差異,計算機經運算發出,提醒用戶及時采取措施,事故損失。●在局部區域,如一個采油站或聯合站內,出現異常情況,如某管線壓力嚴重下降,可自動關閉相關閥門,防止事故發生?!窠y計數據的準確性。本提供各種形式的自動報表,不但節約大量人力,也了因人為因素造成的誤差?!窳啃?。由于采用了無線通訊技術,野外沒有通訊線路,可大大量?!裨诓捎驼尽⒙摵险疽部杀O控每口井或每個采油站的生產情況。此時表示鐵芯以進入磁飽和段)。然后再將電流降為零,如此重復2-3次。在斷開電源前,應將一次繞組短接,才斷開電源。鐵芯退磁完成。此稱開路退磁法。對于有些電流互感器,由于二次繞組的匝數都比較多。若采用開路退磁法,開路的繞組可能產生高電壓。因此可以在二次繞組接上較大的電阻(額定阻抗的10-20倍)。一次繞組通以電流,從零漸變到互感器一次繞組的允許的電流,再漸變到零,如此重復2-3次。由于接有負載鐵芯可能不能完全退磁。由于一次繞組的電流有,過大的話可能燒壞一次繞組。如果接有負載的二次繞組產生電壓不是過高的話,可以加大二次繞組的負載電阻。這樣可以退磁效果。準確度檢查互感器誤差試驗一般采用被測互感器與互感器進行比較。