產品詳情
批發KG AUTO開關KGT-H2R2V2Y代缸KCL-N-W-LB-160DAEYEON轉換器;DY-ADD-C1AO DY-ADD-CCAO DY-ADD-C3AO DY-ADD-AO DY-ADD-C5AO DY-ADD-C6AO
DAEYEON轉換器;DY-ADD-CAAO DY-ADD-CBAO DY-ADD-CCAO DY-ADD-CDAO DY-ADD-COAO
DAEYEON轉換器;DY-ADD-C1NO DY-ADD-CCNO DY-ADD-C3NO DY-ADD-NO DY-ADD-C5NO DY-ADD-C6NO
DAEYEON轉換器;DY-ADD-CANO DY-ADD-CBNO DY-ADD-CCNO DY-ADD-CDNO DY-ADD-CONO
DAEYEON轉換器;DY-ADD-C1AN DY-ADD-CCAN DY-ADD-C3AN DY-ADD-AN DY-ADD-C5AN DY-ADD-C6AN
DAEYEON轉換器;DY-ADD-CAAN DY-ADD-CBAN DY-ADD-CCAN DY-ADD-CDAN DY-ADD-COAN
DAEYEON轉換器;DY-ADD-C1NN DY-ADD-CCNN DY-ADD-C3NN DY-ADD-NN DY-ADD-C5NN DY-ADD-C6NN
DAEYEON轉換器;DY-ADD-CANN DY-ADD-CBNN DY-ADD-CCNN DY-ADD-CDNN DY-ADD-CONN
DAEYEON轉換器;DY-ADD-D1AA DY-ADD-DCAA DY-ADD-D3AA DY-ADD-D4AA DY-ADD-D5AA DY-ADD-D6AA
DAEYEON轉換器;DY-ADD-DAAA DY-ADD-DBAA DY-ADD-DCAA DY-ADD-DDAA DY-ADD-DOAA
DAEYEON轉換器;DY-ADD-D1NA DY-ADD-DCNA DY-ADD-D3NA DY-ADD-D4NA DY-ADD-D5NA DY-ADD-D6NA
DAEYEON轉換器;DY-ADD-DANA DY-ADD-DBNA DY-ADD-DCNA DY-ADD-DDNA DY-ADD-DONA
DAEYEON轉換器;DY-ADD-D1AB DY-ADD-DCAB DY-ADD-D3AB DY-ADD-D4AB DY-ADD-D5AB DY-ADD-D6AB
DAEYEON轉換器;DY-ADD-DAAB DY-ADD-DBAB DY-ADD-DCAB DY-ADD-DDAB DY-ADD-DOAB
DAEYEON轉換器;DY-ADD-D1NB DY-ADD-DCNB DY-ADD-D3NB DY-ADD-D4NB DY-ADD-D5NB DY-ADD-D6NB
DAEYEON轉換器;DY-ADD-DANB DY-ADD-DBNB DY-ADD-DCNB DY-ADD-DDNB DY-ADD-DONB

可以調節升流器電流的調壓器,及負載。[10]注意事項電流互感器-使用注意事項電流互感器[11]運行時,副邊不允許開路。因為一旦開路,原邊電流均成為勵磁電流,使磁通和副邊電壓大大超過正常值而危及人身和設備。因此,電流互感器副邊回路中不許接熔斷器,也不允許在運行時未經旁路就拆下電流表、繼電器等設備。電流互感器運行時,副邊不允許開路。原因如下:⒈電流互感器一次被測電流磁勢I1N1在鐵芯產生磁通Φ1⒉電流互感器二次測量儀表電流磁勢I2N2在鐵芯產生磁通Φ2⒊電流互感器鐵芯合磁通:ΦΦ1+Φ2⒋因為Φ1.Φ2方向相反,大小相等,互相抵消,所以Φ0⒌若二次開路,即I20,則:ΦΦ1,電流互感器鐵芯磁通很強。上一根軌道頂端與樓板間距不大于100mm。長出多余的導軌應使用砂輪鋸掉,嚴禁使用氣焊切割。(3)導軌①拆除導軌支架安裝線,在樣板上確定的轎廂導軌中心線位置放轎廂導軌中心線,并固定好。②用鋼盲尺檢杏導軌端面與轎廂導軌中心線之間的距離,在導軌支架與導軌間用加減墊片的,使各測量點導軌端面與轎廂導軌中心線之間的距離一致。[4]應用編輯導軌具有結構簡單、制造方便、剛度大等優點。但導軌阻力大,磨損快,動、靜因數差別大,低速時易產生爬行現象。為了數控機床的定位精度和運動平穩性,數控機床目前在數控機床上已廣泛采用塑料導軌。其因數小;且動、靜因數相近,運動平穩性好。
DAEYEON轉換器;DY-ADD-D1AC DY-ADD-DCAC DY-ADD-D3AC DY-ADD-D4AC DY-ADD-D5AC DY-ADD-D6AC
DAEYEON轉換器;DY-ADD-DAAC DY-ADD-DBAC DY-ADD-DCAC DY-ADD-DDAC DY-ADD-DOAC
DAEYEON轉換器;DY-ADD-D1NC DY-ADD-DCNC DY-ADD-D3NC DY-ADD-D4NC DY-ADD-D5NC DY-ADD-D6NC
DAEYEON轉換器;DY-ADD-DANC DY-ADD-DBNC DY-ADD-DCNC DY-ADD-DDNC DY-ADD-DONC
DAEYEON轉換器;DY-ADD-D1AO DY-ADD-DCAO DY-ADD-D3AO DY-ADD-D4AO DY-ADD-D5AO DY-ADD-D6AO
DAEYEON轉換器;DY-ADD-DAAO DY-ADD-DBAO DY-ADD-DCAO DY-ADD-DDAO DY-ADD-DOAO
DAEYEON轉換器;DY-ADD-D1NO DY-ADD-DCNO DY-ADD-D3NO DY-ADD-D4NO DY-ADD-D5NO DY-ADD-D6NO
DAEYEON轉換器;DY-ADD-DANO DY-ADD-DBNO DY-ADD-DCNO DY-ADD-DDNO DY-ADD-DONO
DAEYEON轉換器;DY-ADD-D1AN DY-ADD-DCAN DY-ADD-D3AN DY-ADD-D4AN DY-ADD-D5AN DY-ADD-D6AN
DAEYEON轉換器;DY-ADD-DAAN DY-ADD-DBAN DY-ADD-DCAN DY-ADD-DDAN DY-ADD-DOAN設計時應根據具體情況通過編程來選擇保護功能或使某些保護功能失效。《低壓配電設計規范》GB50054-95第4.3.5條規定:“突然斷電比過負載造成的損失更大的線路,其過負載保護應作用于而不應作用于切斷電路。”在前面提到的消防泵控制中,由于消防泵是消防應急負荷,它是在消防救火的緊要關頭工作的。當火災發生時,重要的問題是消防泵能地運轉打水到消防管網中,而對消防泵電機的保護就不是重要問題。所以上面提到的某些保護功能可以通過編程使它失效,或者使保護于而不是作于使消防泵電機停機。前面提到的過載保護功能也只應于。2)支路保護由于軟起動器本身沒有短路保護,為保護其中的晶閘管,應該采用快速熔斷器(自動空氣開關的開斷時間較長。
DAEYEON轉換器;DY-ADD-D1NN DY-ADD-DCNN DY-ADD-D3NN DY-ADD-D4NN DY-ADD-D5NN DY-ADD-D6NN
DAEYEON轉換器;DY-ADD-DANN DY-ADD-DBNN DY-ADD-DCNN DY-ADD-DDNN DY-ADD-DONN
DAEYEON轉換器;DY-ADD-O1AA DY-ADD-OCAA DY-ADD-O3AA DY-ADD-O4AA DY-ADD-O5AA DY-ADD-O6AA
DAEYEON轉換器;DY-ADD-OAAA DY-ADD-OBAA DY-ADD-OCAA DY-ADD-ODAA DY-ADD-OOAA
DAEYEON轉換器;DY-ADD-O1NA DY-ADD-OCNA DY-ADD-O3NA DY-ADD-O4NA DY-ADD-O5NA DY-ADD-O6NA



