產品詳情
批發KG AUTO開關KDX-QMD22A怎么樣氣缸KCD1-L-80-10-NDAEYEON轉換器;DY-HSC-3AAA DY-HSC-3ANA
DAEYEON轉換器;DY-HSC-3BAA DY-HSC-3BNA
DAEYEON轉換器;DY-HSC-3CAA DY-HSC-3CNA
DAEYEON轉換器;DY-HSC-3DAA DY-HSC-3DNA
DAEYEON轉換器;DY-HSC-3OAA DY-HSC-3ONA
DAEYEON轉換器;DY-HSC-41AA DY-HSC-41NA空心線圈往往由漆包線均勻繞制在環形骨架上制成,骨架采用塑料、陶瓷等非鐵磁材料,其相對磁導率與空氣的相對磁導率相同,這是空心線圈有別于帶鐵心的電流互感器的一個顯著特征。(3)鐵心線圈式低功率電流互感器(LPCT)。它是電磁式電流互感器的一種發展。其按照高阻抗電阻設計,在非常高的一次電流下,飽和特性,擴大了測量范圍,了功率消耗,可以無飽和的高準確度測量高達短路電流的過電流、全偏移短路電流,測量和保護可共用一個鐵心線圈式低功率電流互感器,其輸出為電壓。兩者的使用發展方向由于電磁式電流互感器存在的易飽和、非線性及頻帶窄等問題,電子式電流互感器逐漸興起。電子式電流互感器一般具有抗磁飽和、低功耗、寬頻帶等優點。
DAEYEON轉換器;DY-HSC-42AA DY-HSC-42NA
DAEYEON轉換器;DY-HSC-43AA DY-HSC-43NA
DAEYEON轉換器;DY-HSC-44AA DY-HSC-44NA
DAEYEON轉換器;DY-HSC-45AA DY-HSC-45NA
DAEYEON轉換器;DY-HSC-46AA DY-HSC-46NA
DAEYEON轉換器;DY-HSC-4AAA DY-HSC-4ANA
DAEYEON轉換器;DY-HSC-4BAA DY-HSC-4BNA
DAEYEON轉換器;DY-HSC-4CAA DY-HSC-4CNA
DAEYEON轉換器;DY-HSC-4DAA DY-HSC-4DNA
DAEYEON轉換器;DY-HSC-4OAA DY-HSC-4ONA
DAEYEON轉換器;DY-HSC-51AA DY-HSC-51NA
DAEYEON轉換器;DY-HSC-52AA DY-HSC-52NA
DAEYEON轉換器;DY-HSC-53AA DY-HSC-53NA過篩機制將捕獲因尺寸較大, 無法通過過濾結構孔徑的顆粒。ASFLOW生產的超高純管道和管材, 采用了先進的環氧樹脂技術, 可用于半導體和應用。ASFLOW使用的材料
DAEYEON轉換器;DY-HSC-54AA DY-HSC-54NA
DAEYEON轉換器;DY-HSC-55AA DY-HSC-55NA
DAEYEON轉換器;DY-HSC-56AA DY-HSC-56NA
DAEYEON轉換器;DY-HSC-5AAA DY-HSC-5ANA
DAEYEON轉換器;DY-HSC-5BAA DY-HSC-5BNA
DAEYEON轉換器;DY-HSC-5CAA DY-HSC-5CNA
DAEYEON轉換器;DY-HSC-5DAA DY-HSC-5DNA
DAEYEON轉換器;DY-HSC-5OAA DY-HSC-5ONA
DAEYEON轉換器;DY-HSC-61AA DY-HSC-61NA
DAEYEON轉換器;DY-HSC-62AA DY-HSC-62NA
DAEYEON轉換器;DY-HSC-63AA DY-HSC-63NA
DAEYEON轉換器;DY-HSC-64AA DY-HSC-64NA
DAEYEON轉換器;DY-HSC-65AA DY-HSC-65NA
DAEYEON轉換器;DY-HSC-66AA DY-HSC-66NA
DAEYEON轉換器;DY-HSC-6AAA DY-HSC-6ANA
DAEYEON轉換器;DY-HSC-B1AA DY-HSC-B1NA
DAEYEON轉換器;DY-HSC-B2AA DY-HSC-B2NA
DAEYEON轉換器;DY-HSC-B3AA DY-HSC-B3NA
DAEYEON轉換器;DY-HSC-B4AA DY-HSC-B4NA
DAEYEON轉換器;DY-HSC-B5AA DY-HSC-B5NA
DAEYEON轉換器;DY-HSC-B6AA DY-HSC-B6NA
DAEYEON轉換器;DY-HSC-BAAA DY-HSC-BANA
DAEYEON轉換器;DY-HSC-BBAA DY-HSC-BBNA
二次側額定電流通常為1A或5A。其中2×a/C表示同一臺產品有兩種電流比,通過改變產品的連接片接線實現,當串聯時,電流比為a/c,并聯時電流比為2×a/C。一般情況下,計量用電流互感器變流比的選擇應使其一次額定電流I1n不小于線路中的負荷電流(即計算IC)。如線路中負荷計算電流為350A,則電流互感器的變流比應選擇400/5。保護用的電流互感器為保證其準確度要求,可以將變比選得大一些。準確級應根據測量準確度[8]要求選擇電流互感器的準確級并進行校驗。下表為不同準確級電流互感器的誤差限值:電流互感器準確級和誤差限值電流互感器準確級和誤差限值準確級選擇的原則:計費計量用的電流互感器其準確級不低于0.5級;必須是過零點才觸發,導通可控硅。(七)非過零觸發-無論交流電電壓在什么相位的時候都可觸發導通可控硅,常見的是移相觸發,即通過改變正弦交流電的導通角(角相位),來改變輸出百分比。可控硅型號編輯按一機部IBI144一75的規定,普通型可控硅稱為KP型可控硅整流元件(又叫KP型硅閘流管》。普通可控硅的型號采用如下格式標注:圖片1圖片1額定速態平均屯成系列共分為14個,如表1一5所示。正反向重復蜂值屯壓級別規定1000V以下的管子每100V為一級,1000V以上的管子每200V為一級。取電壓教除以100做為級別標志,如表1-6所示。通態平均電壓組別依電壓大小分為9組,用宇毋表示,如表1一所示。例如.KP500-12D表示的是通態平均電流為500A,額定(正反向重復峰值)電壓為1200V。



